Skip to main content
24/7/365 availability
Nationwide coverage across all 50 states
Products · Generators & Light Towers

Generator & light tower rental.

Rent towable diesel generators in 25–500 kW classes, self-contained light towers, and temporary power distribution. LDR coordinates delivery, service, and pickup nationwide.

A towable diesel generator and an LED light tower with its mast raised at dusk.
7,500+Vetted vendors nationwide
10,000+Projects delivered per year
50States covered
24/7/365Live emergency line
Unit Detail

Compare products.

Prime or standby power

Towable diesel generators.

Output25–500 kW classes 4 bands cover office trailers through plant-scale loads.
Voltage120/240 V 1φ · 120/208 or 277/480 V 3φ Field-switchable voltage matches the panel being supplied.
DutyPrime or standby Use for continuous site power or backup behind a transfer switch.
FuelDiesel, on-board tank Extended-run tanks are available for long or unattended operation.
SoundAttenuated enclosure Sound-attenuated configurations suit occupied sites and events.
Configuration
  • Multi-voltage switchboard with cam-lock connections for feeder cable
  • Parallel units for loads beyond one generator's class
A four-lamp LED light tower on a towable chassis
Self-contained site lighting

Light towers.

MastUp to 30 ft, 360° rotation Heads aim independently; outriggers stabilize the tower.
Lamps4 LED or metal-halide heads Metal-halide remains available in some markets. LED runs far longer on a tank.
Run timeMultiple night shifts per tank A full tank can cover multiple night shifts, depending on the unit.
PowerSelf-contained diesel The tower supplies its own power without a site connection.
Configuration
  • On-board diesel generator and fuel tank with no site hookup
  • Outriggers and a towable chassis that repositions as the work moves
  • Quiet-run configurations for events and occupied areas
A temporary power distribution spider box with cabling
Power where the tools are

Temporary power distribution.

Spider box50 A · 120/240 V A standard configuration for jobsite distribution.
ProtectionGFCI at every receptacle Ground-fault protection at the point of use.
CableCam-lock feeders Covered or ramped wherever crews and vehicles cross.
Transformers480 V stepped down 3-phase generator output feeding 120 V tools.
What it does
  • Divides a generator into protected circuits across floors or work areas
  • Matched to the generator's output when the order is placed

Standard sizes shown. Equipment varies by market and manufacturer.

Coordinate related site equipment. Add cold storage, lift equipment, or temporary fencing to the same account and invoice.
All products
Sizing The Unit

Size the generator.

An undersized unit can trip breakers when motors start, while an oversized diesel can run too lightly. Share the connected load, voltage, runtime, and placement details so LDR can size the generator before dispatch.

What we need from you

Information needed to size the generator.

  • Total connected load. List everything that runs at once in kW and the starting demand for motors. Starting demand can be several times the running load. The target operating load is 70–80% of rated output.
  • Voltage and phase. Confirm what the panel accepts: single-phase 120/240 V, or 3-phase 120/208 or 277/480 V. Rental units can be field-switched to match.
  • Run time and fuel plan. Provide the operating hours per day and the refueling plan. Fuel is typically the customer's responsibility, while refueling service and extended-run tanks can be added to the order.
  • Placement and access. Identify the unit location, distance to the load, and access needed for the delivery truck.
Where the classes land

Typical uses by size class.

  • 25–69 kW. Small sites, office trailers, pumps, and telecom work.
  • 70–149 kW. Tools, hoists, site trailers, and midsize facilities during an outage.
  • 150–349 kW. Large facility backup and heavy site power.
  • 350–500 kW. Plant-scale loads. Units can run in parallel for larger loads.
The Rental, End To End

What LDR coordinates.

  • Equipment sourcing. LDR sources the required size and configuration through a network of 7,500+ vetted vendors across all 50 states.
  • Delivery, swaps, and pickup. Service is scheduled to the project dates, including removal when the rental ends.
  • Support if a unit fails. Call LDR for emergency support and replacement equipment if a unit fails under normal use.
  • Vendor and billing paperwork. LDR manages W-9s, vendor vetting, and compliance, then provides one invoice.
Your tasksService scope
01
Arrange a qualified electrician for tie-ins.Panel connections and transfer-switch installation are licensed electrical work.
02
Provide a level, open-air placement area.Keep exhaust and service clearances open because diesel units cannot run indoors.
03
Protect cable runs.Cover cables or route them away from where vehicles and crews cross.
04
Plan for fuel.Fueling options vary. Refueling service and extended-run tanks can be added to the order.
If Something Goes Wrong

Emergency support & maintenance.

The emergency response team answers 24/7/365 and coordinates support or replacement.

Replacement starts with one call.

LDR coordinates emergency support and can get replacement rental equipment to minimize downtime.

Extend the rental if an outage continues.

The contact who placed the order can coordinate swap-outs, additional units, and extensions. 

Add equipment as the scope changes.

Add a light tower, more distribution equipment, or a larger generator through the same account instead of sourcing a separate rental.

Hurricane Helene Response A hospital network kept open through Hurricane Helene
26 medical sites kept powered0 downtime

When Hurricane Helene's flooding disrupted power and water across a major hospital network, LDR delivered commercial-grade generators, lighting, and sanitation to all 26 medical sites. Despite regional shortages and a tight timeline, the sites remained open with 0 downtime.

Read the case study
Call 877-605-2211
Call LDR today, our team is ready to take your call.

FAQs.

What size generator do I need?
Add the kW for everything that runs at once, include the starting demand for motors, and confirm the panel voltage. Share those details, and LDR will calculate the total wattage and select the size before dispatch as part of the order.
Can a generator power an entire construction site?
Yes. A towable generator can power tools, trailers, lighting, HVAC, and temporary offices. Spider boxes and feeder cables distribute protected circuits to the work areas, and larger loads can use several generators in parallel.
Can a generator back up an occupied facility?
Yes. A qualified electrician must install the transfer switch that moves the building between utility and generator power. LDR sizes the unit to the panel and load, while your electrician makes the connection.
How fast can you deliver?
Delivery is often the same day or next day, depending on equipment availability and the market. 
What happens if the generator stops working?
Call immediately. LDR coordinates emergency support and replacement equipment 24/7/365 to minimize downtime.
Are fuel services included?
Fuel is typically the customer's responsibility during the rental, but options vary. Refueling service or extended-run fuel tanks can be added for continuous operation. 
Are light towers suitable for overnight work?
Yes. Light towers support night construction, roadwork, emergency response, and remote sites. A 4-lamp LED tower fueled at dusk can run through the shift without a mid-shift refuel.
Do light towers have LED or metal-halide heads?
LED heads run longer per tank than metal-halide and illuminate immediately. Metal-halide remains available in some markets. LDR confirms the lamp type on the available units before delivery.
How much does it cost to rent generators and light towers?
Price depends on the equipment type and count, rental duration, and market. 
Can you cover more than one site or market?
Yes. LDR coordinates all rentals through one account, contact, and invoice across all the markets where you operate.
Memberships and credentials: ConnexFM memberNational Waste & Recycling Association memberISN member contractor

Request generators & light towers for your site.

Share the load, voltage, runtime, site conditions, and required dates. An account manager will confirm the equipment and delivery window.

No obligation · 24/7/365 · all 50 states